Sign in →

Test Code MYOG Myoglobin, Serum or Plasma

Methodology

Electrochemiluminescence Immunoassay (ECLIA)

Specimen Requirements

Container/Tube:

Preferred: Lithium heparin (light green-top)

Acceptable: Serum Gel

 Draw blood, spin down and send 1 mL (pediatric:  0.2 mL) of plasma or serum.

Specimen Stability Information

 

Specimen Type

Temperature

Time

Serum

Refrigerated, spun

14 days

  RT, spun 8 days

 

Reference Values

Males:  28-72 ng/mL
Females:  25-58 ng/mL

Reject Due To

 

Hemolysis

Mild:

ok

Gross:

ok

Lipemia

Mild:

ok

Gross:

ok

Icterus

Mild:

ok

Gross:

ok

 

Day(s) Test Set Up

Monday through Sunday

CPT Coding

83874

Secondary ID

HHA1475

Performing Laboratory

Huntsville Hospital Laboratory

LOINC Coding

Test name LOINC Code

Myoglobin, Serum or Plasma

2639-3