Sign in →

Test Code LUPUSI Lupus Inhibitor, Plasma

Specimen Requirements

1. Draw blood in a blue-top (citrate) tube(s). Spin down, remove plasma, spin plasma again, and place 3 mL of citrate platelet-poor plasma in plastic vial. (Glass vial is not acceptable.)

Note:  Double-centrifuged specimen is critical for accurate results as platelet contamination may cause spurious results.
2. Freeze specimen immediately at ≤-40° C, if possible.
3. Send specimen frozen.
Note:  Each coagulation assay requested should have its own vial.

Specimen Stability Information

 

Specimen Type

Temperature

Time

Platelet -poor plasma, citrated

RT, spun

4 hrs
 

Frozen,spun and separated

14 days

 

Reference Values

Negative for lupus inhibitor

Reject Due To

 

Hemolysis

Mild:

ok

Gross:

Reject

Lipemia

Mild:

ok

Gross:

ok

Icterus

Mild:

ok

Gross:

ok

 

Day(s) Test Set Up

Monday, Thursday

CPT Coding

85732

Secondary ID

HHA1245

Performing Laboratory

Huntsville Hospital Laboratory