Sign in →

Test Code INSUL Insulin, Serum or Plasma

Methodology

Electrochemiluminescence Immunoassay (ECLIA)

Specimen Requirements

Container/Tube:

Preferred: Lithium heparin (light green-top)

Acceptable: Serum Gel

 Draw blood from a fasting patient (non fasting specimens are accepted for special studies).  Spin down and send 1 mL (pediatric:  0.2 mL) of plasma or serum

Notes:

1. Patients with a history of insulin usage may have insulin antibodies which cause an inaccurate assay result.
2. If multiple specimens are drawn, send separate request form for each specimen.
3. Label specimens appropriately (corresponding draw time).

Specimen Stability Information

 

Specimen Type

Temperature

Time

Plasma,lithium heparin / Serum

RT, spun

4 hrs
 

Refrigerated, spun

48 hrs

 

Reference Values

 3-17 µU/mL

Reject Due To

 

Hemolysis

Mild:

Reject

Gross:

Reject

Lipemia

Mild:

ok

Gross:

ok

Icterus

Mild:

ok

Gross:

ok

 

Day(s) Test Set Up

Monday through Sunday

CPT Coding

83525 

Secondary ID

HHA1443

Performing Laboratory

Huntsville Hospital Laboratory

LOINC Coding

Test Name LOINC Code

Insulin, Serum or Plasma

20448-7