Sign in →

Test Code AT3 Antithrombin III Activity, Plasma

Methodology

Chromogenic Substrate

Specimen Requirements

1. Draw blood in a blue-top (citrate) tube(s). Spin down, remove plasma, spin plasma again, and place 0.5 mL of citrate platelet-poor plasma in plastic vial. (Glass vial is not acceptable.)

Note:  Double-centrifuged specimen is critical for accurate results as platelet contamination may cause spurious results.
2. Freeze specimen immediately at ≤-40° C, if possible.
3. Send specimen frozen.
Note:  1. Each coagulation assay requested should have its own vial.
2. Heparin treatment may lower plasma antithrombin.

Specimen Stability Information

 

Specimen Type

Temperature

Time

Platelet poor plasma, citrated Frozen

14 days

 

Reference Values

80-120%

Reject Due To

 

Hemolysis

Mild:

ok

Gross:

Reject

Lipemia

Mild:

ok

Gross:

ok

Icterus

Mild:

ok

Gross:

ok

 

Day(s) Test Set Up

Tuesday, Friday

CPT Coding

85300

Secondary ID

HHA1209

Performing Laboratory

Huntsville Hospital Laboratory

LOINC Coding

Test Name LOINC Code

Antithrombin III Activity, Plasma

27811-9