Sign in →

Test Code A1C Hemoglobin A1c, Blood

Methodology

High-Pressure Liquid Chromatography (HPLC)

Specimen Requirements

Draw blood in a lavender-top (EDTA) tube(s), and send 1 mL (pediatric:  0.2 mL) of EDTA whole blood refrigerated.

Specimen Stability Information

 

Specimen Type

Temperature

Time

Whole blood, EDTA

Refrigerated

7 days

 

Reference Values

4.0 % -5.6 %

 

The following HbA1c ranges recommended by the American Diabetic Association may be used as aid in the diagnosis of diabetes mellitus.

    HbA1c%     Suggested Diagnosis        

             ≥6.5     Diabetic        

          5.7-6.4   Pre-Diabetic       

            <5.7      Non-Diabetic  

In diabetic patients, the following HbA1c ranges may be used for interpretation of results:

     HbA1c%    Glycemic Goal

            <8.0     Less Stringent Goal

            <7.0     General Goal

            <6.5     More Stringent Goal

 

Reject Due To

 

Hemolysis

NA

Lipemia

NA

Icterus

NA

 

Day(s) Test Set Up

Monday through Saturday

CPT Coding

83036

Secondary ID

HHA1261

Performing Laboratory

Huntsville Hospital Laboratory

LOINC Coding

Test Name LOINC Code
Hemoglobin A1c

4548-4